Phthalonitrile resin PN-3М cured 180°C

Want to keep this datasheet? Save it now in your required format

Description

PN-3M is a single part phthalonitrile resin with higher glass transition temperature and outstanding thermal stability, specially developed for vacuum infusion and RTM technologies. Pre-curing at 180°C allows to remove parts from tool after cooling. Post-curing provides glass transition temperature above 450°C. Moreover, PN-3M does not support combustion. Can be used for high temperature tooling up to 450°C. It shows the following features and properties:


  • One-part resin system
  • Epoxy-like processability
  • Incombustible
  • Decomposition temperature 520°C
  • Low moisture saturation
  • Low softening temperature 80°C
  • Diese Materialdaten wurden von Matmatch zur Verfügung gestellt

    Alle Daten beziehen sich auf Raumtemperatur soweit nicht anderweitig spezifiziert. SI Einheiten werden verwendt soweit nicht anderweitig spezifiziert.
    Äquivalente Standards sind ähnlich zu einem oder mehreren Standards die der Anbieter angegeben hat. Manche äquivalente Standards können strikter sein oder außerhalb der Bedingungen des ursprünglichen Standards.

    Ashby charts

    See where falls on the material property chart for against in your materials selection and design process. Our Ashby charts are interactive with more technical data upon clicking. Sign up to get access to this premium feature for free.

    Eigenschaften

    Allgemein

    PropertyTemperatureValueComment

    Dichte

    23.0 °C

    1.34 g/cm³

    Show Material materials with Dichte of 1.34 g/cm³

    ASTM D792

    Mechanisch

    PropertyTemperatureValueComment

    Biegefestigkeit

    23.0 °C

    4.6 MPa

    Show Material materials with Biegefestigkeit of 4.6 MPa

    ASTM D790

    Biegemodul

    23.0 °C

    4.6 GPa

    Show Material materials with Biegemodul of 4.6 GPa

    ASTM D790

    Elastizitätsmodul

    23.0 °C

    4.8 GPa

    Show Material materials with Elastizitätsmodul of 4.8 GPa

    ASTM D638

    Plane-Strain Fracture Toughnes

    23.0 °C

    0.76 MPa·√m

    Show Material materials with Plane-Strain Fracture Toughnes of 0.76 MPa·√m

    ASTM D5045

    Zugfestigkeit

    23.0 °C

    60 MPa

    Show Material materials with Zugfestigkeit of 60 MPa

    ASTM D638

    Formänderungsenergieabgabe

    ASTM D5045

    Thermisch

    PropertyTemperatureValueComment

    Koeffizient der thermischen Ausdehnung

    23.0 °C

    9E-5 1/K

    Show Material materials with Koeffizient der thermischen Ausdehnung of 9E-5 1/K

    ASTM E831

    Vicat-Erweichungstemperatur

    80 °C

    Show Material materials with Vicat-Erweichungstemperatur of 80 °C

    Wärmeformbeständigkeitstemperatur

    200 °C

    Show Material materials with Wärmeformbeständigkeitstemperatur of 200 °C

    ASTM E2092

    Magnetisch

    PropertyValue

    Curie-Temperatur

    180 °C

    Show Material materials with Curie-Temperatur of 180 °C

    Technological properties

    Property
    Application areas

    Structures requiring high heat resistance;Parts requiring non-combustibility;Parts of engines and other special applications;High temperature tooling for thermoplastics

    Processing methods

    Assemble the vacuum bag. Perform a leak test, the rate of the vacuum drop should not be more than 1 mbar per minute. The residual pressure in the bag must not be more than 10 mbar. Assemble the second vacuum bag, put airweave material between the layers of the vacuum film. Perform a leak test for the second vacuum bag. The residual pressure in the bag must not be more than 10 mbar. Degas for 30-40 minutes, at 150-160°C, at a pressure of no more than 10 mbar. During the degassing, the resin should be stirred intensively. Heat the tool up to 150-170°C. Maintaining the temperature of resin dispenser at 160°C, start the infusion process. After complete impregnation of the bag, close the resin inputs, but continue evacuation from the inner bag for at least 30 minutes. Then close the outputs from the inner bag. Maintain the outer vacuum bag until the end of curing process. Increase the temperature at a rate of 2°C/min to 180°C. Dwell at 180°C for 6 hours. Before removing the part, cool the mold to at least 60°C at a speed of no more than 5°C/min. Post-cure can be performed without tooling. Heat to 180°C at a rate of 2°C/min, then heat to 375°C at a rate of 5-10°C/min. Dwell at 375°C for 8 hours. Cool down the part to 60°C at rate <5°C/min. For the measurement of vacuum, the use of absolute pressure sensors is recommended.