Phthalonitrile resin PN-3М cured 180°C

Want to keep this datasheet? Save it now in your required format

Description

PN-3M is a single part phthalonitrile resin with higher glass transition temperature and outstanding thermal stability, specially developed for vacuum infusion and RTM technologies. Pre-curing at 180°C allows to remove parts from tool after cooling. Post-curing provides glass transition temperature above 450°C. Moreover, PN-3M does not support combustion. Can be used for high temperature tooling up to 450°C. It shows the following features and properties:


  • One-part resin system
  • Epoxy-like processability
  • Incombustible
  • Decomposition temperature 520°C
  • Low moisture saturation
  • Low softening temperature 80°C
  • Los datos sobre este material han sido proporcionados por Matmatch.

    A menos que se indique lo contrario, todas las medidas corresponden a condiciones de temperatura ambiente. A menos que se indique lo contrario, se utilizan las unidades del SI.
    Las normas armonizadas son similares a uno o varios estándares del proveedor. Es posible que algunas normas armonizadas se ajusten al estándar original, mientras que otras pueden quedar fuera de su alcance.

    Ashby charts

    See where falls on the material property chart for against in your materials selection and design process. Our Ashby charts are interactive with more technical data upon clicking. Sign up to get access to this premium feature for free.

    Propiedades

    General

    PropertyTemperatureValueComment

    Densidad

    23.0 °C

    1.34 g/cm³

    Show Material materials with Densidad of 1.34 g/cm³

    ASTM D792

    Mecánica

    PropertyTemperatureValueComment

    Módulo de flexión

    23.0 °C

    4.6 GPa

    Show Material materials with Módulo de flexión of 4.6 GPa

    ASTM D790

    Módulo elástico

    23.0 °C

    4.8 GPa

    Show Material materials with Módulo elástico of 4.8 GPa

    ASTM D638

    Plane-Strain Fracture Toughnes

    23.0 °C

    0.76 MPa·√m

    Show Material materials with Plane-Strain Fracture Toughnes of 0.76 MPa·√m

    ASTM D5045

    Resistencia a la flexión

    23.0 °C

    4.6 MPa

    Show Material materials with Resistencia a la flexión of 4.6 MPa

    ASTM D790

    Resistencia a la tracción

    23.0 °C

    60 MPa

    Show Material materials with Resistencia a la tracción of 60 MPa

    ASTM D638

    Liberación de energía de deformación

    ASTM D5045

    Aplicaciones térmicas

    PropertyTemperatureValueComment

    Coeficiente de dilatación térmica

    23.0 °C

    9E-5 1/K

    Show Material materials with Coeficiente de dilatación térmica of 9E-5 1/K

    ASTM E831

    Temperatura de flexión bajo carga

    200 °C

    Show Material materials with Temperatura de flexión bajo carga of 200 °C

    ASTM E2092

    Temperatura de reblandecimiento Vicat

    80 °C

    Show Material materials with Temperatura de reblandecimiento Vicat of 80 °C

    Magnético

    PropertyValue

    Temperatura de Curie

    180 °C

    Show Material materials with Temperatura de Curie of 180 °C

    Technological properties

    Property
    Application areas

    Structures requiring high heat resistance;Parts requiring non-combustibility;Parts of engines and other special applications;High temperature tooling for thermoplastics

    Processing methods

    Assemble the vacuum bag. Perform a leak test, the rate of the vacuum drop should not be more than 1 mbar per minute. The residual pressure in the bag must not be more than 10 mbar. Assemble the second vacuum bag, put airweave material between the layers of the vacuum film. Perform a leak test for the second vacuum bag. The residual pressure in the bag must not be more than 10 mbar. Degas for 30-40 minutes, at 150-160°C, at a pressure of no more than 10 mbar. During the degassing, the resin should be stirred intensively. Heat the tool up to 150-170°C. Maintaining the temperature of resin dispenser at 160°C, start the infusion process. After complete impregnation of the bag, close the resin inputs, but continue evacuation from the inner bag for at least 30 minutes. Then close the outputs from the inner bag. Maintain the outer vacuum bag until the end of curing process. Increase the temperature at a rate of 2°C/min to 180°C. Dwell at 180°C for 6 hours. Before removing the part, cool the mold to at least 60°C at a speed of no more than 5°C/min. Post-cure can be performed without tooling. Heat to 180°C at a rate of 2°C/min, then heat to 375°C at a rate of 5-10°C/min. Dwell at 375°C for 8 hours. Cool down the part to 60°C at rate <5°C/min. For the measurement of vacuum, the use of absolute pressure sensors is recommended.