VDM® Alloy 400

Nombres alternativos y comerciales
Nicorros, Monel, VDM® Alloy 400
Want to keep this datasheet? Save it now in your required format

Description

2.4360 (NiCu30Fe) is a single-phase, solid solution, nickel-copper alloy with excellent corrosion resistance in a wide range of corrosive media that shows the following features and properties:


  • Resistance against chloride-induced stress corrosion
  • Excellent strength even at low application temperatures
  • Easy processing compared to other high-alloy materials
  • approved for pressure vessels from -10 to 425°C (14 to 797°F) pursuant to VdTÜV Material Sheet 263 and up to 480°C (896°F) in accordance with ASME Boiler and Pressure Vessel Code
  • Equivalent Materials

    Los datos sobre este material han sido proporcionados por VDM Metals.

    A menos que se indique lo contrario, todas las medidas corresponden a condiciones de temperatura ambiente. A menos que se indique lo contrario, se utilizan las unidades del SI.
    Las normas armonizadas son similares a uno o varios estándares del proveedor. Es posible que algunas normas armonizadas se ajusten al estándar original, mientras que otras pueden quedar fuera de su alcance.

    Ashby charts

    See where falls on the material property chart for against in your materials selection and design process. Our Ashby charts are interactive with more technical data upon clicking. Sign up to get access to this premium feature for free.

    Propiedades

    General

    PropertyTemperatureValue

    Densidad

    23.0 °C

    8.82 g/cm³

    Show Supplier Material materials with Densidad of 8.82 g/cm³

    Mecánica

    PropertyTemperatureValueComment

    Dureza Rockwell B

    23.0 °C

    150 [-]

    Show Supplier Material materials with Dureza Rockwell B of 150 [-]

    Annealed, room temperature, DIN, VdTÜV

    Elongación

    23.0 °C

    25 %

    Show Supplier Material materials with Elongación of 25 %

    min., Sheet, plate, rod, bar at stress-relieved condition

    Límite elástico Rp 0,2

    20.0 °C

    175 MPa

    Show Supplier Material materials with Límite elástico Rp 0,2 of 175 MPa

    100.0 °C

    150 MPa

    Show Supplier Material materials with Límite elástico Rp 0,2 of 150 MPa

    200.0 °C

    135 MPa

    Show Supplier Material materials with Límite elástico Rp 0,2 of 135 MPa

    300.0 °C

    130 MPa

    Show Supplier Material materials with Límite elástico Rp 0,2 of 130 MPa

    400.0 °C

    130 MPa

    Show Supplier Material materials with Límite elástico Rp 0,2 of 130 MPa

    425.0 °C

    130 MPa

    Show Supplier Material materials with Límite elástico Rp 0,2 of 130 MPa

    Módulo elástico

    20.0 °C

    182 GPa

    Show Supplier Material materials with Módulo elástico of 182 GPa

    100.0 °C

    180 GPa

    Show Supplier Material materials with Módulo elástico of 180 GPa

    200.0 °C

    177 GPa

    Show Supplier Material materials with Módulo elástico of 177 GPa

    300.0 °C

    170 GPa

    Show Supplier Material materials with Módulo elástico of 170 GPa

    400.0 °C

    165 GPa

    Show Supplier Material materials with Módulo elástico of 165 GPa

    500.0 °C

    150 GPa

    Show Supplier Material materials with Módulo elástico of 150 GPa

    Unlock all property charts

    Resistencia a la tracción

    20.0 °C

    450 MPa

    Show Supplier Material materials with Resistencia a la tracción of 450 MPa

    100.0 °C

    420 MPa

    Show Supplier Material materials with Resistencia a la tracción of 420 MPa

    200.0 °C

    390 MPa

    Show Supplier Material materials with Resistencia a la tracción of 390 MPa

    300.0 °C

    380 MPa

    Show Supplier Material materials with Resistencia a la tracción of 380 MPa

    400.0 °C

    370 MPa

    Show Supplier Material materials with Resistencia a la tracción of 370 MPa

    425.0 °C

    370 MPa

    Show Supplier Material materials with Resistencia a la tracción of 370 MPa

    Unlock all property charts

    Resistencia al choque, ensayo Charpy entallado

    23.0 °C

    1500 kJ/m²

    Show Supplier Material materials with Resistencia al choque, ensayo Charpy entallado of 1500 kJ/m²

    Average value, room temperature, annealed condition

    Aplicaciones térmicas

    PropertyTemperatureValue

    Calor específico

    20.0 °C

    452 J/(kg·K)

    Show Supplier Material materials with Calor específico of 452 J/(kg·K)

    100.0 °C

    461 J/(kg·K)

    Show Supplier Material materials with Calor específico of 461 J/(kg·K)

    200.0 °C

    473 J/(kg·K)

    Show Supplier Material materials with Calor específico of 473 J/(kg·K)

    300.0 °C

    484 J/(kg·K)

    Show Supplier Material materials with Calor específico of 484 J/(kg·K)

    400.0 °C

    495 J/(kg·K)

    Show Supplier Material materials with Calor específico of 495 J/(kg·K)

    500.0 °C

    523 J/(kg·K)

    Show Supplier Material materials with Calor específico of 523 J/(kg·K)

    600.0 °C

    544 J/(kg·K)

    Show Supplier Material materials with Calor específico of 544 J/(kg·K)

    700.0 °C

    555 J/(kg·K)

    Show Supplier Material materials with Calor específico of 555 J/(kg·K)

    800.0 °C

    566 J/(kg·K)

    Show Supplier Material materials with Calor específico of 566 J/(kg·K)

    900.0 °C

    577 J/(kg·K)

    Show Supplier Material materials with Calor específico of 577 J/(kg·K)

    1000.0 °C

    587 J/(kg·K)

    Show Supplier Material materials with Calor específico of 587 J/(kg·K)

    1150.0 °C

    603 J/(kg·K)

    Show Supplier Material materials with Calor específico of 603 J/(kg·K)

    Unlock all property charts

    Coeficiente de dilatación térmica

    100.0 °C

    1.38E-5 1/K

    Show Supplier Material materials with Coeficiente de dilatación térmica of 1.38E-5 1/K

    200.0 °C

    1.45E-5 1/K

    Show Supplier Material materials with Coeficiente de dilatación térmica of 1.45E-5 1/K

    300.0 °C

    1.49E-5 1/K

    Show Supplier Material materials with Coeficiente de dilatación térmica of 1.49E-5 1/K

    400.0 °C

    1.52E-5 1/K

    Show Supplier Material materials with Coeficiente de dilatación térmica of 1.52E-5 1/K

    500.0 °C

    1.56E-5 1/K

    Show Supplier Material materials with Coeficiente de dilatación térmica of 1.56E-5 1/K

    600.0 °C

    1.6E-5 1/K

    Show Supplier Material materials with Coeficiente de dilatación térmica of 1.6E-5 1/K

    700.0 °C

    1.64E-5 1/K

    Show Supplier Material materials with Coeficiente de dilatación térmica of 1.64E-5 1/K

    800.0 °C

    1.68E-5 1/K

    Show Supplier Material materials with Coeficiente de dilatación térmica of 1.68E-5 1/K

    900.0 °C

    1.73E-5 1/K

    Show Supplier Material materials with Coeficiente de dilatación térmica of 1.73E-5 1/K

    Unlock all property charts

    Conductividad térmica

    20.0 °C

    23 W/(m·K)

    Show Supplier Material materials with Conductividad térmica of 23 W/(m·K)

    100.0 °C

    25.4 W/(m·K)

    Show Supplier Material materials with Conductividad térmica of 25.4 W/(m·K)

    200.0 °C

    28.7 W/(m·K)

    Show Supplier Material materials with Conductividad térmica of 28.7 W/(m·K)

    300.0 °C

    31.9 W/(m·K)

    Show Supplier Material materials with Conductividad térmica of 31.9 W/(m·K)

    400.0 °C

    34.7 W/(m·K)

    Show Supplier Material materials with Conductividad térmica of 34.7 W/(m·K)

    500.0 °C

    38.4 W/(m·K)

    Show Supplier Material materials with Conductividad térmica of 38.4 W/(m·K)

    600.0 °C

    41.2 W/(m·K)

    Show Supplier Material materials with Conductividad térmica of 41.2 W/(m·K)

    700.0 °C

    43.1 W/(m·K)

    Show Supplier Material materials with Conductividad térmica of 43.1 W/(m·K)

    800.0 °C

    45.1 W/(m·K)

    Show Supplier Material materials with Conductividad térmica of 45.1 W/(m·K)

    900.0 °C

    47.5 W/(m·K)

    Show Supplier Material materials with Conductividad térmica of 47.5 W/(m·K)

    1000.0 °C

    50 W/(m·K)

    Show Supplier Material materials with Conductividad térmica of 50 W/(m·K)

    1150.0 °C

    52.9 W/(m·K)

    Show Supplier Material materials with Conductividad térmica of 52.9 W/(m·K)

    Unlock all property charts

    Temperatura de fusión

    1300 - 1350 °C

    Show Supplier Material materials with Temperatura de fusión of 1300 - 1350 °C

    Eléctrico

    PropertyTemperatureValue

    Resistividad eléctrica

    20.0 °C

    5.13E-7 Ω·m

    Show Supplier Material materials with Resistividad eléctrica of 5.13E-7 Ω·m

    100.0 °C

    5.4E-7 Ω·m

    Show Supplier Material materials with Resistividad eléctrica of 5.4E-7 Ω·m

    200.0 °C

    5.55E-7 Ω·m

    Show Supplier Material materials with Resistividad eléctrica of 5.55E-7 Ω·m

    300.0 °C

    5.75E-7 Ω·m

    Show Supplier Material materials with Resistividad eléctrica of 5.75E-7 Ω·m

    400.0 °C

    5.85E-7 Ω·m

    Show Supplier Material materials with Resistividad eléctrica of 5.85E-7 Ω·m

    500.0 °C

    6E-7 Ω·m

    Show Supplier Material materials with Resistividad eléctrica of 6E-7 Ω·m

    600.0 °C

    6.18E-7 Ω·m

    Show Supplier Material materials with Resistividad eléctrica of 6.18E-7 Ω·m

    700.0 °C

    6.35E-7 Ω·m

    Show Supplier Material materials with Resistividad eléctrica of 6.35E-7 Ω·m

    800.0 °C

    6.55E-7 Ω·m

    Show Supplier Material materials with Resistividad eléctrica of 6.55E-7 Ω·m

    900.0 °C

    6.75E-7 Ω·m

    Show Supplier Material materials with Resistividad eléctrica of 6.75E-7 Ω·m

    Unlock all property charts

    Magnético

    PropertyValue

    Temperatura de Curie

    20 - 50 °C

    Show Supplier Material materials with Temperatura de Curie of 20 - 50 °C

    Chemical properties

    PropertyValueComment

    Aluminio

    0.5 %

    Show Supplier Material materials with Aluminio of 0.5 %

    max.

    Carbono

    0.15 %

    Show Supplier Material materials with Carbono of 0.15 %

    max.

    Cobre

    28 - 34 %

    Show Supplier Material materials with Cobre of 28 - 34 %

    Hierro

    1 - 2.5 %

    Show Supplier Material materials with Hierro of 1 - 2.5 %

    Manganeso

    2 %

    Show Supplier Material materials with Manganeso of 2 %

    max.

    Níquel

    63 %

    Show Supplier Material materials with Níquel of 63 %

    Silicona

    0.5 %

    Show Supplier Material materials with Silicona of 0.5 %

    max.

    Technological properties

    Property
    Application areas

    Brine heater and recompression evaporator in saltworks, sulfuric and hydrofluoric acid alkylation, heat exchangers in the chemical industry, plating components for mineral oil distillation plants, splash zone lining on offshore platforms, impellers and pump shafts in marine technology, refining plants for the production of nuclear fuel, pumps and valves in production lines for tetrachlorethylene (perchlorethylene) and chlorinated plastics, heating tubes for monoethanolamine (MEA), sour-gas resistant components for oil and gas production. Alloy 400 is approved for pressure vessels from -10 to 425 °C pursuant to VdTÜV Material Sheet 263 and up to 480 °C in accordance with ASME Boiler and Pressure Vessel Code.

    Cold Forming

    VDM® Alloy 400 is easily cold-shaped. However, it has a slightly higher work-hardening than does carbon steel. This must be taken into account during design and selection of forming tools and equipment and during the planning of forming processes. Intermediate annealing is necessary during cold working. The strength of VDM® Alloy 400 can be increased by hardening, though. Stress relief annealing is recommended in such cases, though, especially when used in media that can cause stress corrosion cracking in nickel-copper alloys, such as mercury and its compounds or fluorosilicic acid.

    Corrosion properties

    VDM® Alloy 400 has excellent resistance to neutral and alkaline salts and has long been the standard material for salt production systems. VDM® Alloy 400 is one of the few materials which can be used in contact with fluorine, hydrofluoric acid and hydrogen fluoride or their compounds. The material has a very high resistance to alkaline media. Its behavior in seawater is also excellent compared to copper-based alloys with an increased resistance to cavitation. VDM® Alloy 400 can be used in contact with highly diluted mineral acids, such as sulfuric and hydrochloric acid, provided that they are not ventilated. Since the alloy does not contain chromium, the corrosion rates can increase significantly under oxidizing conditions. While VDM® Alloy 400 is resistant to stress corrosion cracking, it can display stress cracks in the presence of mercury or in moist, aerated HF vapors. Stress relief annealing is necessary in these conditions.

    General machinability

    VDM® Alloy 400 can be easily machined in the soft-annealed condition. Strain-hardened, stress relieved material is a more favorable processing behavior in most machining processes. Since the alloy has a tendency to hardening, a low cutting speed should be selected and the cutting tool should stay engaged at all times. An adequate depth of cut is important in order to cut below the previously formed work-hardened zone. Optimum heat dissipation through the use of large quantities of suitable, preferably aqueous, lubricants has considerable influence on a stable machining process.

    Heat Treatment

    The soft annealing should be performed at temperatures of 700 to 900°C (1,292 to 1,652°F), preferably at about 825°C (1,517°F). The retention time commences with material temperature equalization of the workpiece. Cooling down should be accelerated with air to achieve optimum corrosion-protection properties. To form a fine grain structure, the observance of heat treatment temperature and time is very important. The values are to be set precisely. Under certain circumstances, an increase in strength by cold forming is advantageous. Stress-relief annealing at about 550 to 650°C (1,022 to 1,202°F) should then occur, in order to prevent stress corrosion cracking

    Hot forming

    VDM® Alloy 400 can be hot formed in the temperature range of 800 to 1,200°C (1,472 to 2,192°F), but only slight deformations should occur at 925°C (1,697°F). Hot bending is performed from 1,200 to 1,025°C (2,192 to 1,877°F). For preheating, the workpieces may be placed in the furnace which has already been preheated to the maximum hot forming temperature. The workpieces should remain in the furnace for around 60 minutes per 100 mm (3.94 in) of thickness once the furnace has reached its temperature again. After this, the workpiece should be removed from the furnace immediately and formed within the temperature interval stated above. Heat treatment after hot forming is recommended for the achievement of optimal mechanical properties and corrosion resistance.

    Other

    VDM® Alloy 400 is a binary nickel-copper alloy with a face-centered cubic microstructure.

    Welding

    The material VDM® Alloy 400 is welded with the common welding processes, such as GTAW (TIG), GTAW (TIG) hot wire, plasma, GMAW (MIG/MAG) and submerged arc welding. The material should be in its annealed condition for welding and should be free of scale, grease and markings. During welding, everything has to be scrupulously clean.