EN 10106 Grade M1300-100A

Want to keep this datasheet? Save it now in your required format

Description

Non-oriented fully processed electrical steel have guaranteed magnetic properties, in accordance with (or exceeding the levels required by) EN 10106:2015. As well as the maximum loss and minimum polarisation levels cited, full magnetic characterisation curves regarding losses, polarisation, permeability and apparent power at different frequencies are available on request.

This standard grade is available so that a steel grade can be selected according to the specific requirements of each application, from low alloy grades offering the advantage of excellent magnetic permeability, thermal conductivity and punchability to alloyed grades offering the advantage of very low losses, even at higher frequencies. A wide range of coatings is available, allowing further enhancement of punchability, reduction of interlaminar losses and improvement of corrosion protection.

Related Standards

Equivalent Materials

This material data has been provided by ArcelorMittal.

"Typical" values were obtained via a literature search. "Predicted" values were imputed via artificial intelligence technology. While we have placed significant efforts in ensuring data accuracy, "typical" and "predicted" data should be considered indicative and verified by appropriate material testing. Please do contact us if additional information on the the predicted data method is required.
All metrics apply to room temperature unless otherwise stated. SI units used unless otherwise stated.
Equivalent standards are similar to one or more standards provided by the supplier. Some equivalent standards may be stricter whereas others may be outside the bounds of the original standard.

Ashby charts

Properties

General

PropertyValueComment

Density

7.8 g/cm³

Show Supplier Material materials with Density of 7.8 g/cm³

for thickness 1 mm

Mechanical

PropertyValueComment

Elongation

30 - 40 %

Show Supplier Material materials with Elongation of 30 - 40 %

for thickness 1 mm | Transverse | A80

Hardness, Vickers

120 - 150 [-]

Show Supplier Material materials with Hardness, Vickers of 120 - 150 [-]

for thickness 1 mm

Number of bends

10 [-]

Show Supplier Material materials with Number of bends of 10 [-]

min. for thickness 1 mm | Guaranteed

Tensile strength

390 - 430 MPa

Show Supplier Material materials with Tensile strength of 390 - 430 MPa

for thickness 1 mm | Transverse

Yield strength

260 - 300 MPa

Show Supplier Material materials with Yield strength of 260 - 300 MPa

for thickness 1 mm | Transverse

Yield to strength ratio

0.66 - 0.71 [-]

Show Supplier Material materials with Yield to strength ratio of 0.66 - 0.71 [-]

for thickness 1 mm

Magnetic

PropertyValueFrequencyComment

Anisotropy of loss

6 %

Show Supplier Material materials with Anisotropy of loss of 6 %

(+/-) for thickness 1 mm | Guaranteed

Guaranteed core loss

13 W/kg

Show Supplier Material materials with Guaranteed core loss of 13 W/kg

50Hz

max. for thickness 1 mm | at 1.5 T

Guaranteed polarization

1.6 [-]

Show Supplier Material materials with Guaranteed polarization of 1.6 [-]

min. | for thickness 1 mm | at 2500 A/m

1.7 [-]

Show Supplier Material materials with Guaranteed polarization of 1.7 [-]

min. | for thickness 1 mm | at 5000 A/m

1.78 [-]

Show Supplier Material materials with Guaranteed polarization of 1.78 [-]

min. | for thickness 1 mm | at 10000 A/m

Stacking factor

0.98 mm

Show Supplier Material materials with Stacking factor of 0.98 mm

min. | for thickness 1 mm | Guaranteed

Typical core loss

5.8 W/kg

Show Supplier Material materials with Typical core loss of 5.8 W/kg

50Hz

max. for thickness 1 mm | at 1 T

17.34 W/kg

Show Supplier Material materials with Typical core loss of 17.34 W/kg

60Hz

max. for thickness 1 mm | at 1.5 T

Technological properties

Property
Application areas

The fully processed steel is designed for the manufacture of magnetic circuits for motors, transformers and other electrical equipment. The principal applications are in the electrical engineering, domestic appliance, automotive and building industries. Low loss fully processed steels are also suitable for shielding applications at low frequencies (e.g. housings around electrical systems).

Coating

This standard grade is available non-insulated or varnished with any of the coating types described in the following link https://industry.arcelormittal.com/catalogue/D28/EN .

Other

Recommendations for use


The are obtained without heat treatment after stamping.

The material as supplied possesses all the required magnetic properties.


Dimensions:




NotesBefore side trimmingSide trimmedSlit coilsSheet length 400 to 2500 mm
Min widthMax widthMin widthMax widthMin widthMax widthMin widthMax width
M1300-100A2 & 310301250600122020600--
2 & 3. Side trimmed: max width 1250 after prior agreement; Slit coils: after prior agreement regarding widths between 20 and 44 mm