Melamine-phenol-formaldehyde Reinforced with 40% Wood Powder and 10% Mineral Powder (MP+WD40+MD10), Type 182

Alternative and trade names
Melopas®
Want to keep this datasheet? Save it now in your required format

Description

Phenol-modified melamine with excellent surface hardness, good mechanical properties, good electrical properties and good heat resistance

Ashby charts

See where Melamine-phenol-formaldehyde Reinforced with 40% Wood Powder and 10% Mineral Powder (MP+WD40+MD10), Type 182 falls on the material property chart for Density against Elastic modulus in your materials selection and design process. Our Ashby charts are interactive with more technical data upon clicking. Sign up to get access to this premium feature for free.

Properties

General

Density

ρ

1.45 - 1.65 g/cm³ at 20 °C

Mechanical

Elastic modulus

E

6.5 - 9 GPa at 20 °C

Show Melamine formaldehyde (MF) materials with Elastic modulus of 6.5 - 9 GPa at 20 °C

Impact strength, Charpy notched

Ivnot

1.3 - 1.65 kJ/m² at 20 °C

Show Melamine formaldehyde (MF) materials with Impact strength, Charpy notched of 1.3 - 1.65 kJ/m² at 20 °C

Impact strength, Charpy unnotched

Iunnot

3.5 - 10 kJ/m² at 20 °C

Show Melamine formaldehyde (MF) materials with Impact strength, Charpy unnotched of 3.5 - 10 kJ/m² at 20 °C

Tensile strength

Rm

55 - 75 MPa at 20 °C

Show Melamine formaldehyde (MF) materials with Tensile strength of 55 - 75 MPa at 20 °C

Thermal

Coefficient of thermal expansion

α

2.5E-5 - 4E-5 1/K at 20 °C

Flammability

UL 94 V0

Max service temperature, long

Tmaxlong

135 °C

Max service temperature, short

160 °C

Thermal conductivity

λ

0.3 - 0.45 W/(m·K) at 20 °C

Electrical

Dielectric constant

εr

8 - 13.5 [-] at 20 °C

Electrical resistivity

ρel

1.00E+10 - 1.00E+11 Ω·m at 20 °C

Optical

Transparency

no

Technological properties

Application areas

Contact strips, contact clamps, screw caps

Fillers

40% Wood Powder and 10% Mineral Powder

Processing methods

Injection molding, compression molding

This material data has been provided by M-Base.

All metrics apply to room temperature unless otherwise stated. SI units used unless otherwise stated.
Equivalent standards are similar to one or more standards provided by the supplier. Some equivalent standards may be stricter whereas others may be outside the bounds of the original standard.