Epoxy NU 463 V

Alternative and trade names
Epoxy NU 463 V
Want to keep this datasheet? Save it now in your required format

Description

Glass fibre reinforced encapsulation epoxy moulding compound with very good mechanical properties and excellent crack resistance with Shelf life of 12 months at temperatures below 8°C

Ashby charts

See where Epoxy NU 463 V falls on the material property chart for Density against Elastic modulus in your materials selection and design process. Our Ashby charts are interactive with more technical data upon clicking. Sign up to get access to this premium feature for free.

Properties

General

Density

ρ

1.9 g/cm³ at 20 °C

DIN 53479

Water absorption

cwater

0.08 % at 20 °C

ISO 62, 100°C/30 min

Mechanical

Elastic modulus

E

15 GPa at 20 °C

Show Epoxy Resin (EP) materials with Elastic modulus of 15 GPa at 20 °C

ISO 178 (Flexural Test)

Elongation

A

1.5 % at 20 °C

Show Epoxy Resin (EP) materials with Elongation of 1.5 % at 20 °C

ISO 178

Flexural strength

σbend

180 MPa at 20 °C

Show Epoxy Resin (EP) materials with Flexural strength of 180 MPa at 20 °C

ISO 178

Impact strength, Charpy notched

Ivnot

3 kJ/m² at 20 °C

Show Epoxy Resin (EP) materials with Impact strength, Charpy notched of 3 kJ/m² at 20 °C

ISO 179-1

Impact strength, Charpy unnotched

Iunnot

16 kJ/m² at 20 °C

Show Epoxy Resin (EP) materials with Impact strength, Charpy unnotched of 16 kJ/m² at 20 °C

ISO 179-1

Tensile strength

Rm

110 MPa at 20 °C

Show Epoxy Resin (EP) materials with Tensile strength of 110 MPa at 20 °C

ISO 527

Thermal

Coefficient of thermal expansion

α

2.4E-5 1/K at 20 °C

ISO 11359-2, Mean value for 20-105°C

Glass transition temperature

Tg

110 °C

ISO 6721-7

Thermal conductivity

λ

0.85 W/(m·K) at 20 °C

ISO 8894

Electrical

Comparative tracking index

CTI

250 V at 20 °C

IEC 60112

Dielectric constant, 50Hz

εr,50Hz

4.7 [-] at 20 °C

IEC 60250

Dielectric strength

EDS

23 kV/mm at 20 °C

IEC 60243-1, 3mm Plate

Electrical resistivity

ρel

1.00E+13 Ω·m at 20 °C

IEC 60093

Loss tangent, 50Hz

tanδ50,Hz

1.3 [-] at 20 °C

IEC 60250

Technological properties

Application areas

Encapsulation of electrical devices e.g. Solenoids, Stators, Transformer

Filler Type

Fillers

Glass Fiber

This material data has been provided by Duresco GmbH.

All metrics apply to room temperature unless otherwise stated. SI units used unless otherwise stated.
Equivalent standards are similar to one or more standards provided by the supplier. Some equivalent standards may be stricter whereas others may be outside the bounds of the original standard.