Epoxy RT511H - Tube

Alternative and trade names
NEMA GRADE: G-11, Type, U.L. LISTED: N
Want to keep this datasheet? Save it now in your required format

Description

Being a heat treated version of RT511, RT511H uses a heavy weave glass fabric substrate meeting all of the requirements of NEMA G-10, with the added feature of having excellent strength at elevated temperatures.

Properties

General

Density

ρ

1.78 g/cm³ at 23 °C

ASTM D792

Moisture absorption

cmoisture

0.1 % at 23 °C

ASTM D570, Condition D₁-24/23

Mechanical

Compressive modulus

Ecomp

7.58 MPa at 23 °C

Show Thermoset Polymer Matrix Composite materials with Compressive modulus of 7.58 MPa at 23 °C

ASTM D695, Condition A

Compressive strength

Rmc

344.74 MPa at 23 °C

Show Thermoset Polymer Matrix Composite materials with Compressive strength of 344.74 MPa at 23 °C

ASTM D695, Condition A

Hardness, Rockwell M

HRM

115 [-] at 23 °C

Show Thermoset Polymer Matrix Composite materials with Hardness, Rockwell M of 115 [-] at 23 °C

ASTM D785

Tensile strength

Rm

272.34 MPa at 23 °C

Show Thermoset Polymer Matrix Composite materials with Tensile strength of 272.34 MPa at 23 °C

ASTM D638, Condition A

Thermal

Flammability

UL Bulletin 94, Class HB

Glass transition temperature

Tg

170 °C

Min., DMA

Relative temperature index, electrical

RTIel

200 °C

¹

Relative temperature index, mechanical strength

RTIstr

200 °C

¹

Electrical

Breakdown voltage

Ubreak

55 - 60 kV at 23 °C

ASTM D149, Condition A (Min.) & D-48/50 (Max.)

Dielectric strength

EDS

14.37 kV/mm at 23 °C

ASTM D149, Condition A

Technological properties

Application areas

Typical applications include bushings, spacers and structural parts for power generation equipment.

Fillers

Glass Fabric

Other

1.This temperature is a recommendation only, and based upon experience in various applications. The maximum operating temperature is dependent upon the application and should be investigated prior to use


2.The mechanical properties are converted from American unit system to International unit system.

Primary Phase

Secondary Phase

Supplier Disclaimer

This data, while believed to be accurate and based on reliable analytical methods, is for informational purposes only. The terms and conditions of the agreement under which it is sold will govern any sales of this product. Data supplied above are "typical values"; not to be considered "specification values".


To assure the material's performance is adequate for a specific application; customers should verify, independent of Norplex-Micarta, performance characteristics of interest.


It is the responsibility of the users of this information to make sure that they have the latest version of this TDB, and are urged to check with Customer Service or, preferably our web site, www.norplex-micarta.com, to determine if the information is the most current available.

This material data has been provided by Norplex Micarta.

All metrics apply to room temperature unless otherwise stated. SI units used unless otherwise stated.