General
Property | Value | Testing Standard | Comment |
---|---|---|---|
Density | 1.85 g/cm³ Show Supplier Material materials with Density of 1.85 g/cm³ | ASTM D349 | |
Moisture absorption | 0.08 % Show Supplier Material materials with Moisture absorption of 0.08 % | ASTM D349 | Condition A |
Mechanical
Property | Value | Testing Standard | Comment |
---|---|---|---|
Compressive strength | 507.5 MPa Show Supplier Material materials with Compressive strength of 507.5 MPa | ASTM D349 | Condition A |
Flexural strength | 522.6 MPa Show Supplier Material materials with Flexural strength of 522.6 MPa | ASTM D349 | Condition T155 |
588.1 MPa Show Supplier Material materials with Flexural strength of 588.1 MPa | ASTM D349 | Condition A | |
Hardness, Rockwell M | 110 [-] Show Supplier Material materials with Hardness, Rockwell M of 110 [-] | ASTM D349 | |
Tensile strength | 385.4 MPa Show Supplier Material materials with Tensile strength of 385.4 MPa | ASTM D349 | Condition A |
Thermal
Property | Value | Comment | |
---|---|---|---|
Relative temperature index, electrical | 170 °C Show Supplier Material materials with Relative temperature index, electrical of 170 °C | ¹ | |
Relative temperature index, mechanical strength | 180 °C Show Supplier Material materials with Relative temperature index, mechanical strength of 180 °C | ¹ | |
Flammability | UL 94, Class HB |
Electrical
Property | Value | Frequency | Testing Standard | Comment |
---|---|---|---|---|
Dielectric constant | 4.3 [-] Show Supplier Material materials with Dielectric constant of 4.3 [-] | 1MHz | ASTM D349 | Condition A |
Dielectric strength | 5.31 kV/mm Show Supplier Material materials with Dielectric strength of 5.31 kV/mm | ASTM D349 | Condition A | |
Dissipation factor | 0.004 [-] Show Supplier Material materials with Dissipation factor of 0.004 [-] | 1MHz | ASTM D349 | Condition A |
Technological properties
Property | ||
---|---|---|
Fillers | Glass Fabric | |
Other | 1.This temperature is a recommendation only, and based upon experience in various applications. The maximum operating temperature is dependent upon the application and should be investigated prior to use 2.The mechanical properties are converted from American unit system to International unit system. | |
Supplier Disclaimer | This data, while believed to be accurate and based on reliable analytical methods, is for informational purposes only. The terms and conditions of the agreement under which it is sold will govern any sales of this product. Data supplied above are "typical values"; not to be considered "specification values". To assure the material's performance is adequate for a specific application; customers should verify, independent of Norplex-Micarta, performance characteristics of interest. It is the responsibility of the users of this information to make sure that they have the latest version of this TDB, and are urged to check with Customer Service or, preferably our web site, www.norplex-micarta.com, to determine if the information is the most current available. |