Properties

General

Density

ρ

2.7 - 2.71 g/cm³ at 20 °C

Dimension

Dimensions

Dicke

Mechanical

Elastic modulus

E

69 GPa at 20 °C

Elongation

A

5.3 - 8 % at 20 °C

Elongation A50

A50

1 - 8 % at 20 °C

Fatigue strength

SNf

45 MPa at 20 °C

for 5x10⁸ cycles

Hardness, Brinell

HB

30 - 38 [-] at 20 °C

500 kg load, 10 mm ball

Plane-Strain Fracture Toughnes

KIC

22 - 35 MPa·√m at 20 °C

Typical for Wrought 1000 Series Aluminium

Poisson's ratio

ν

0.33 [-] at 20 °C

Typical for Wrought 1000 Series Aluminium

Shear modulus

G

25 GPa at 20 °C

Shear strength

τ

70 MPa at 20 °C

Tensile strength

Rm

95 - 130 MPa at 20 °C

Yield strength

YS

98 MPa at 20 °C

Yield strength Rp0.2

Rp0.2

75 - 105 MPa at 20 °C

Thermal

Coefficient of thermal expansion

α

2.36E-5 - 2.4E-5 1/K at 20 °C

Hide chart

Melting point

Tm

645 - 655 °C

Specific heat capacity

cp

900 J/(kg·K) at 20 °C

Thermal conductivity

λ

230 - 234 W/(m·K) at 20 °C

Electrical

Electrical conductivity

σel

3.50E+7 - 3.60E+8 S/m at 20 °C

Electrical resistivity

ρel

2.78E-8 - 2.86E-8 Ω·m at 20 °C

Chemical properties

Element

Weight %

Comment

Other

-

each 0.03

Al

99.6 - 100 %

Cu

0 - 0.05 %

Fe

0 - 0.35 %

Mg

0 - 0.03 %

More

Technological properties

Brazing

general: possible with commercial processes and methods

Corrosion properties

Stress corrosion cracking: no damage during operation and laboratory tests, general: very good, without protection in industrial or seawater atmosphere

General machinability

General: not suitable (O, H12), poor (H14, H16, H18)

Workability

general (condition): good (O, H12, H14), acceptable (H16, H18)