General
Property | Value | Condition | Related Standards |
---|---|---|---|
Density | 2.71 g/cm³ Show Material materials with Density of 2.71 g/cm³ | H113 | AA Standards, ASTM B210, ASTM B483 |
2.8 g/cm³ Show Material materials with Density of 2.8 g/cm³ | H113 |
Mechanical
Property | Value | Condition | Related Standards | Comment |
---|---|---|---|---|
Elastic modulus | 69.0 GPa Show Material materials with Elastic modulus of 69.0 GPa | H113 | AA Standards, ASTM B210, ASTM B483 | |
Plane-Strain Fracture Toughnes | 22.0 - 35.0 MPa·√m Show Material materials with Plane-Strain Fracture Toughnes of 22.0 - 35.0 MPa·√m | Typical for Wrought 1000 Series Aluminium | ||
Poisson's ratio | 0.33 [-] Show Material materials with Poisson's ratio of 0.33 [-] | Typical for Wrought 1000 Series Aluminium | ||
Shear modulus | 25.9 GPa Show Material materials with Shear modulus of 25.9 GPa | Typical for Wrought 1000 Series Aluminium | ||
Tensile strength | 75.0 MPa Show Material materials with Tensile strength of 75.0 MPa | H113 | AA Standards, ASTM B210, ASTM B483 | |
86.0 MPa Show Material materials with Tensile strength of 86.0 MPa | H113 | |||
Yield strength | 25.0 MPa Show Material materials with Yield strength of 25.0 MPa | H113 | AA Standards, ASTM B210, ASTM B483 | RP02 |
29.0 MPa Show Material materials with Yield strength of 29.0 MPa | H113 |
Thermal
Property | Temperature | Value | Condition | Related Standards |
---|---|---|---|---|
Coefficient of thermal expansion | 2.4e-05 1/K Show Material materials with Coefficient of thermal expansion of 2.4e-05 1/K | H113 | ||
20 °C | 2.36e-05 1/K Show Material materials with Coefficient of thermal expansion of 2.36e-05 1/K | H113 | AA Standards, ASTM B210, ASTM B483 | |
100 °C | 2.36e-05 1/K Show Material materials with Coefficient of thermal expansion of 2.36e-05 1/K | H113 | AA Standards, ASTM B210, ASTM B483 | |
Melting point | 640.0 - 655.0 °C Show Material materials with Melting point of 640.0 - 655.0 °C | H113 | AA Standards, ASTM B210, ASTM B483 | |
640.0 °C Show Material materials with Melting point of 640.0 °C | H113 | |||
Specific heat capacity | 900.0 J/(kg·K) Show Material materials with Specific heat capacity of 900.0 J/(kg·K) | H113 | ||
Thermal conductivity | 218.0 - 222.0 W/(m·K) Show Material materials with Thermal conductivity of 218.0 - 222.0 W/(m·K) | H113 | AA Standards, ASTM B210, ASTM B483 | |
220.0 W/(m·K) Show Material materials with Thermal conductivity of 220.0 W/(m·K) | H113 |
Electrical
Property | Value | Condition | Related Standards |
---|---|---|---|
Electrical conductivity | 33000000.0 - 34000000.0 S/m Show Material materials with Electrical conductivity of 33000000.0 - 34000000.0 S/m | H113 | AA Standards, ASTM B210, ASTM B483 |
Electrical resistivity | 2.94e-08 - 3.03e-08 Ω·m Show Material materials with Electrical resistivity of 2.94e-08 - 3.03e-08 Ω·m | H113 | AA Standards, ASTM B210, ASTM B483 |
Chemical properties
Property | Value | Condition | Related Standards |
---|---|---|---|
Aluminium | 99.0 % Show Material materials with Aluminium of 99.0 % | H113 | AA Standards, ASTM B210, ASTM B483 |
99.0 - 100.0 % Show Material materials with Aluminium of 99.0 - 100.0 % | H113 | ||
Copper | 0.05 - 0.2 % Show Material materials with Copper of 0.05 - 0.2 % | H113 | AA Standards, ASTM B210, ASTM B483 |
Iron | 1.0 % Show Material materials with Iron of 1.0 % | H113 | |
Manganese | 0.05 % Show Material materials with Manganese of 0.05 % | H113 | AA Standards, ASTM B210, ASTM B483 |
Other | 0.15 % Show Material materials with Other of 0.15 % | H113 | |
Silicon | 1.0 % Show Material materials with Silicon of 1.0 % | H113 | |
Zinc | 0.1 % Show Material materials with Zinc of 0.1 % | H113 | AA Standards, ASTM B210, ASTM B483 |
Technological properties
Property | ||
---|---|---|
Brazing | general: possible with commercial processes and methods | |
Corrosion properties | Stress corrosion cracking: no damage during operation and laboratory tests, general: very good, without protection in industrial or seawater atmosphere | |
General machinability | General: not suitable (O, H12), poor (H14, H16, H18) | |
Workability | general (condition): good (O, H12, H14), acceptable (H16), poor(H18) |