Show me around

AA Standards Grade 1350 O

Want to keep this datasheet? Save it now in your required format

Description

Related Standards

Equivalent Materials

Ashby charts

See where AA Standards Grade 1350 O falls on the material property chart for Density against Elastic modulus in your materials selection and design process. Our Ashby charts are interactive with more technical data upon clicking. Sign up to get access to this premium feature for free.

Properties

General

Density

ρ

2.7 - 2.71 g/cm³ at 20 °C

Mechanical

Elastic modulus

E

69 GPa at 20 °C

Elongation

A

23 % at 20 °C

Plane-Strain Fracture Toughnes

KIC

22 - 35 MPa·√m at 20 °C

Typical for Wrought 1000 Series Aluminium

Poisson's ratio

ν

0.33 [-] at 20 °C

Typical for Wrought 1000 Series Aluminium

Shear modulus

G

25.9 GPa at 20 °C

Typical for Wrought 1000 Series Aluminium

Tensile strength

Rm

78 - 85 MPa at 20 °C

Yield strength

YS

29 MPa at 20 °C

Yield strength Rp0.2

Rp0.2

30 MPa at 20 °C

Thermal

Coefficient of thermal expansion

α

2.36E-5 - 2.4E-5 1/K at 20 °C

Hide chart

Melting point

Tm

645 - 655 °C

Specific heat capacity

cp

900 J/(kg·K) at 20 °C

Thermal conductivity

λ

230 - 234 W/(m·K) at 20 °C

unstated value

Unlock all property charts

Create your account on Matmatch to view all property charts and access other premium features for free.

Sign in

Electrical

Electrical conductivity

σel

3.60E+7 - 3.60E+8 S/m at 20 °C

Electrical resistivity

ρel

2.78E-8 - 2.79E-8 Ω·m at 20 °C

Typical value

Chemical properties

Element

Weight %

Comment

Al

99.5 - 100 %

B

0 - 0.05 %

Cr

0 - 0.01 %

Cu

0 - 0.05 %

Ga

0 - 0.03 %

More

Technological properties

Brazing

general: possible with commercial processes and methods

Corrosion properties

Stress corrosion cracking: no damage during operation and laboratory tests, general: very good, without protection in industrial or seawater atmosphere

General machinability

General: not suitable (O, H12, H111), poor (H14, H24, H16, H26, H18)

Workability

general (condition): good (O, H12, H111, H14, H24), acceptable (H16, H26, H18)

This material data has been provided by MakeItFrom.com,WroughtAl_ElectricalResistivity,WroughtAl_Thermal,AluKey.

All metrics apply to room temperature unless otherwise stated. SI units used unless otherwise stated.